500W Switch Power Supply
500W Switch Power Supply
|
Feature
- Screw/Rail amphibious installation.
- Natural cooling.
- 100% Heavy Load test.
- Output voltage can be modified:3V~200VDC
- Convenient installation.
- Voltage digital display
Model: |
FP500D-12M |
FP500D-12MDA
(digital) |
FP500D-24M |
FP500D-24MDA
(digital) |
FP500D-68M |
FP500D-68MDA
(digital) |
DC voltage |
12V |
24V |
68V |
Rated voltage |
41.6A |
20.8A |
7.3A |
Current range |
0~41.6A |
0~20.8A |
0~7.3A |
Rated power |
300W |
500W |
300W |
Ripple and Noise |
120mVp-p |
240mVp-p |
240mVp-p |
Voltage adjustment range |
14~17V |
28~34V |
70~75V |
Linear adjust rate |
±1% |
±1% |
±1% |
Load adjust rate |
±2% |
±2% |
±2% |
Output voltage adjusted ±% |
V1:+12V ±10% |
V1:+24V ±10% |
V1:+68V ±10% |
Efficiency |
±82% min |
±82% min |
±82% min |
Vibration test |
2G ,10~500Hz , 3axes |
Input range |
90~132/180~264VAC |
Output |
200~380VDC |
Keep time |
13ms |
Input frequency |
47~440Hz |
Impulse current(25 ℃) |
20A/110VAC 40A/220VAC |
Working temperature |
-15~+50℃ |
Work humidity |
5~+95%RH |
Storage temperature |
-20~+85℃ |
Keep time is in the 110 VAC input and rated load test.
Size chart
•Load current: each group output can provide the maximum load , but the total load not more than rating.
•Line adjust rate: In rated load, from low voltage to high voltage detection.
•Load adjustment rate: in 110 VAC input ,from 20% to 100% of the rated load test.
•Ripple and noise: in 110 VAC input and rated load use a 0.1 UF / 630 V metal capacitance and a 47 UF electrolytic parallel to do the test.
• Efficiency: In the 110 VAC input and rated load test.
-
|
|
| Switching Power Supplies
FP Switch Power Supplies
FLP series (Price Competition)
Solid-state relay
|