Feature
• Two-color double-sided board display, resolution 1/1000;
• Reaction time 1ms~2500ms adjustable;
• Have 2 more output independent, 2 output and 1 of them can be used as alarm output, when not in use can be set to null;
• 1 voltage analog output, or can be used as voltage analog input;
Procurement
Models |
FKP70□P-□□□-□□□ |
FKP70□C-□□□-□□□ |
Rated pressure range
|
-0.101 ~ 1.000MPa |
-101.3 ~ 101.3KPa |
Setting pressure range |
-0.100 ~ 1.000MPa |
-101.0 ~ 101.3KPa |
Max. Anti-Pressure |
1.5MPa |
500KPa |
Suitable Gas |
Non-corrosive gas, non-flammable gas ISO 8573-1:2010 [7:4:4] |
Operating Voltage |
12~24VDC ±10% |
Current consumption |
45mA Below no loading |
Displaying at different pressures |
Kpa |
-- |
0.1 |
Mpa |
0.001 |
-- |
kgf/cm 2 |
0.01 |
0.001 |
Bar |
0.01 |
0.001 |
Psi |
0.1 |
0.01 |
mmHg |
-- |
0.1 |
inchHg |
-- |
1 |
Comparing Outputs |
NPN Outputs
Maximum load current: 100mA
Maximum supply voltage: 30VDC
Internal pressure drop: 1.5V or less |
PNP Outputs
Maximum load current: 100mA
Maximum supply voltage: 30VDC
Internal pressure drop: 1.5V or less |
Voltage Range Outputs |
Output voltage: 1 to 5 VDC ±2.5% F.S.
Linear: ±1%F.S.
Output impedance: approx. 1KΩ |
Current Range Outputs |
Output current: 4 to 20mA ±2.5% F.S.
Linear: .1%F.S.
Load resistance: min. 50Ω, max. 300 Ω@12V; 600Ω@24V |
Display Resolution |
-1%F.S., 1-digit (use temperature 25 ± 10℃) |
Response Time |
1ms *Note: 1
2.0ms, 50ms, 100ms, 250ms, 500ms, ect, |
Monitor Display |
Three colors (Red, orange, Yellow, Green) |
Temperature Features |
±1% F.S (25℃) |
Operating |
0~50℃, 35~85% RH (No Dew) |
Storage |
0~50℃, 35~85% RH (No Dew) |
Protection Class |
IP40 |
Connections |
R, R1/8 + M5
G, G1/8 + M5
N, NPT1/8 + M5 |
Weight |
Approx. 85g included 2M cable |
Accessary |
2M cable*1pc, Manuel*1pc, metallic brackets *1pc |
Wiring Diagram
Dimensions of panel, unit: mm
Dimensions of Accessories, unit: mm
|